reversed-phase comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.
Last reviewed on 2025-06-26. Where a claim depends on a specific study, the study is described rather than over-claimed.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
The pathway can be activated by a range of signals, including hormones, growth factors and components of the extracellular matrix (ECM). It is stimulated by binding of an extracellular ligand to a receptor tyrosine kinase (RTK) in the plasma membrane, causing receptor dimerization and cross-phosphorylation of tyrosine residues in the intracellular domains. The regulatory subunit p85 binds to phosphorylated tyrosine residues on the activated receptor via its Src homology 2 (SH2) domain. It then recruits the catalytic subunit p110 to form the fully active PI3K enzyme. Alternatively, adaptor molecule Grb2 binds to phospho-YXN motifs of the RTK and recruits p85 via Grb2-associated binding (GAB) scaffold protein. The p110 subunit can also be recruited independently of p85. For example, Grb2 can also bind the Ras-GEF Sos1, leading to activation of Ras. Ras-GTP then activates the p110 subunit of PI3K. Other adaptor molecules such as insulin receptor substrate (IRS) can also activate p110.
Azurin is a small, periplasmic, bacterial blue copper protein found in Pseudomonas, Bordetella, or Alcaligenes bacteria. Azurin moderates single-electron transfer between enzymes associated with the cytochrome chain by undergoing oxidation-reduction between Cu(I) and Cu(II). Each monomer of an azurin tetramer has a molecular weight of approximately 14kDa, contains a single copper atom, is intensively blue, and has a fluorescence emission band centered at 308 nm. Azurins and pseudoazurins participate in the denitrification processes in bacteria., including the gram-negative bacteria Pseudomonas aeruginosa, by interacting with cytochrome c551. Azurin from P aeruginosa is a type I blue copper protein (cupredoxin), while cytochrome c551 (9 kDa) is a haem-containing cytochrome. Azurin possesses a relatively large hydrophobic patch close to the active site, and two residues in this hydrophobic patch, Met-44 and Met-64, are believed to be involved in its interaction with the redox partners cytochrome c551 and nitrite reductase. Although unrelated to its electron-transfer property, azurin has been found to have anticancer properties through its interaction with tumor-suppressor protein p53.
Eculizumab (Soliris) appears to be useful for atypical hemolytic uremic syndrome (aHUS). In September 2011 the U.S. Food and Drug Administration (FDA) approved it as an orphan drug to treat people with aHUS. This approval was based on two small prospective trials of 17 people and 20 people. In the UK, NICE issued guidance on the use of Eculizumab for treating aHUS, based on five evidence sources, including those used by the FDA No randomised controlled trials were identified. All prospective studies were phase 2, open‑label, non‑randomised, single‑arm studies that included patients with different clinical baseline characteristics. The prospective studies lasted 26 weeks; however, patients were allowed to continue treatment with eculizumab in a long‑term extension study. Ravulizumab-cwvz (Ultomiris) is a second generation monoclonal antibody for aHUS made by Alexion pharmaceuticals, Inc. The target of ravulizumab-cwvz is the same eculizumab (Soliris) with changes to the structure of the antibody resulting in a longer serum half life and therefore reduced dosing regimen.
After the Netherlands in World War II in 1945, Korvezee returned to Delft, initially serving as a curator and, from 1948, as a lecturer in theoretical chemistry. Although an expert in radioactivity, she had no role in the planning of the reactor center later built on the university's grounds. When the chair became vacant following Scheffer's retirement, Korvezee was passed over once more. In 1954, the Department of Chemical Technology created an extraordinary professorship for her in the emerging field of theoretical chemistry largely regarded as compensation for the chairs she had earlier missed. Her appointment on 14 April 1954, making her the first female professor at Delft, received extensive press coverage. As a full professor, however, she retained the salary of her former lectureship. As professor, Korvezee supervised doctoral and master's students and published more than forty scientific works before 1940, many co-authored with fellow female assistants. She was a member of the Association of Women with an Academic Education (VVAO), though she was never actively involved in the women's movement despite being widely regarded as a feminist figure.
Sources: en.wikipedia.org
Amyloid is formed through the polymerization of hundreds to thousands of monomeric peptides or proteins into long fibers. Amyloid formation involves a lag phase (also called nucleation phase), an exponential phase (also called growth phase) and a plateau phase (also called saturation phase), as shown in the figure. When the quantity of fibrils is plotted versus time, a sigmoidal time course is observed reflecting the three distinct phases. In the simplest model of 'nucleated polymerization' (marked by red arrows in the figure below), individual unfolded or partially unfolded polypeptide chains (monomers) convert into a nucleus (monomer or oligomer) via a thermodynamically unfavourable process that occurs early in the lag phase. Fibrils grow subsequently from these nuclei through the addition of monomers in the exponential phase. A different model, called 'nucleated conformational conversion' and marked by blue arrows in the figure below, was introduced later on to fit some experimental observations: monomers have often been found to convert rapidly into misfolded and highly disorganized oligomers distinct from nuclei. Only later on, will these aggregates reorganise structurally into nuclei, on which other disorganised oligomers will add and reorganise through a templating or induced-fit mechanism (this 'nucleated conformational conversion' model), eventually forming fibrils.
Even with all the precautions taken by medical professionals, infection reportedly occurs in up to 13.9% of patients after stabilization of an open fracture, and in about 0.5-2% of patients who receive joint prostheses. To reduce these numbers, the surfaces of the devices used in these procedures have been altered in hopes of preventing the growth of the bacteria that leads to these infections. This has been achieved by coating titanium devices with an antiseptic combination of chlorhexidine and chloroxylenol. This antiseptic combination successfully prevents the growth of the five main organisms that cause medical-related infections, which include Staphylococcus epidermidis, Methicillin-resistant Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli and Candida albicans. Peptide-based gel coating with intrinsic antibacterial activity against Methicillin-resistant Staphylococcus aureus, was also shown to inhibit colonization of titanium implants in mice.
In order to regulate the secretion of ACTH, many substances secreted within this axis exhibit slow/intermediate and fast feedback-loop activity. Glucocorticoids secreted from the adrenal cortex work to inhibit CRH secretion by the hypothalamus, which in turn decreases anterior pituitary secretion of ACTH. Glucocorticoids may also inhibit the rates of POMC gene transcription and peptide synthesis. The latter is an example of a slow feedback loop, which works on the order of hours to days, whereas the former works on the order of minutes. The half-life of ACTH in human blood is reported to be between ten and 30 minutes. ACTH consists of 39 amino acids, the first 13 of which (counting from the N-terminus) may be cleaved to form α-melanocyte-stimulating hormones (α-MSH) (this common structure is responsible for excessively tanned skin in Addison's disease). After a short period of time, ACTH is cleaved into α-melanocyte-stimulating hormone (α-MSH) and CLIP, a peptide with unknown activity in humans. In the human body, total weight ACTH is 4540 Da.
Sources: en.wikipedia.org
Alloxan is a toxic glucose analogue, which selectively destroys insulin-producing cells in the pancreas (that is, beta cells) when administered to rodents and many other animal species. This causes an insulin-dependent diabetes mellitus (called "alloxan diabetes") in these animals, with characteristics similar to type 1 diabetes in humans. Alloxan is selectively toxic to insulin-producing pancreatic beta cells because it preferentially accumulates in beta cells through uptake via the GLUT2 glucose transporter. Studies suggest alloxan does not cause diabetes in humans. Others found a significant difference in alloxan plasma levels in children with and without type 1 diabetes. Alloxan (C4H2N2O4) readily undergoes redox cycling with its one-electron (C4H3N2O4• semiquinone) and two-electron (dialuric acid, C4H4N2O4) reduction products. In the presence of intracellular reductants such as glutathione (or other thiols), this leads to the generation of toxic reactive oxygen species (ROS) via the interaction of alloxan reduction products with molecular oxygen and related species:
Another common example is the reaction of a primary amine or secondary amine with a carboxylic acid or with a carboxylic acid derivative to form an amide. This reaction is widely used, especially in the synthesis of peptides. On the simple addition of an amine to a carboxylic acid, a salt of the organic acid and base is obtained. To overcome this, the carboxylic acid first needs to be "activated". This is usually done by converting the acid into a more reactive derivative (i.e. anhydride, acid halide) or by using a coupling agent. In some cases, high temperatures (>200 °C) can overcome salt formation by driving off water, without the need for "activation" of the carboxyl group. The downside to this simple reaction is that the compounds may decompose at these elevated temperatures. The carboxylic acid derivatives can be esters, anhydrides, acid halides or any other activated species. The choice of activated carboxyl group or coupling agent can be very important in peptide synthesis, as using the wrong one can lead to racemization.
Automated iterative homologation enables stepwise construction of carbon chains through repeated one-carbon extensions of boronic esters. Two reactions adapted to automation are the Matteson homologation, which inserts a methylene unit via chloromethyllithium, and chiral carbenoid homologation, which uses lithiated benzoate esters. Both methods have been implemented on robotic platforms under low-temperature, inert conditions. Using these techniques, up to six consecutive C(sp³)–C(sp³) bond-forming homologations have been performed without manual intervention, representing the highest number reported in an automated synthesis. The approach has also been applied to the synthesis of intermediates of the natural product (+)-kalkitoxin.
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.