If you have been reading about Quality control and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2025-06-12. Numbers and descriptions here follow the published literature rather than marketing material.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
| Property | Value | Notes |
|---|---|---|
| Accuracy | Recovery near 100% | Depends on acceptance criteria and matrix |
| Precision | Relative standard deviation | Often at or below 2% for replicate injections |
| Limit of detection | Signal-to-noise ratio 3:1 | Approximate and method-specific |
| Limit of quantitation | Signal-to-noise ratio 10:1 | Confirmed by precision and accuracy |
| Resolution | 1.5 or greater | Typical system suitability target |
Developing an HPLC test begins with defining the analytes, matrix, and required reporting limits. Chemists select a separation mode, column chemistry, mobile phase composition, flow rate, and detection wavelength or mass transition. Experiments then adjust these variables to achieve adequate retention, resolution, and peak shape. System suitability tests confirm that the instrument and method perform consistently before sample analysis. Without suitable resolution, quantitative results may be unreliable. Preliminary runs often use scouting gradients to locate retention windows.
Validation establishes that a method is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, robustness, and stability of standards and samples. Acceptance criteria are defined in advance, and results are documented in a validation report. Regulatory guidance for pharmaceuticals, foods, and environmental testing differs, so the applicable framework must be identified. Ongoing verification uses control samples and trend charts after validation. Method transfer to another laboratory may require partial revalidation.
Most routine HPLC testing uses reversed-phase columns, where the stationary phase is nonpolar and the mobile phase is a polar mixture such as water with an organic solvent. Analytes partition between the two phases according to polarity, size, and charge. Gradients that change solvent composition over time can separate compounds with broad retention ranges. Isocratic conditions keep solvent composition constant and suit simpler mixtures. The choice of column chemistry, pH, and temperature affects selectivity and peak shape.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
H3A (aq) + H2O (l) ⇌ H3O+ (aq) + H2A− (aq) Ka1 H2A− (aq) + H2O (l) ⇌ H3O+ (aq) + HA2− (aq) Ka2 HA2− (aq) + H2O (l) ⇌ H3O+ (aq) + A3− (aq) Ka3 An inorganic example of a triprotic acid is orthophosphoric acid (H3PO4), usually just called phosphoric acid. All three protons can be successively lost to yield H2PO−4, then HPO2−4, and finally PO3−4, the orthophosphate ion, usually just called phosphate. Even though the positions of the three protons on the original phosphoric acid molecule are equivalent, the successive Ka values differ since it is energetically less favorable to lose a proton if the conjugate base is more negatively charged. An organic example of a triprotic acid is citric acid, which can successively lose three protons to finally form the citrate ion. Although the subsequent loss of each hydrogen ion is less favorable, all of the conjugate bases are present in solution. The fractional concentration, α (alpha), for each species can be calculated. For example, a generic diprotic acid will generate 3 species in solution: H2A, HA−, and A2−. The fractional concentrations can be calculated as below when given either the pH (which can be converted to the [H+]) or the concentrations of the acid with all its conjugate bases:
The presence of autoantibodies against citrullinated proteins in rheumatoid arthritis patients was first described in the mid-1970s when the biochemical basis of antibody reactivity against keratin and filaggrin was investigated. Subsequent studies demonstrated that autoantibodies from RA patients react with a series of different citrullinated antigens, including fibrinogen, deiminated Epstein–Barr virus nuclear antigen 1 and vimentin, which is a member of the intermediate filament family of proteins. Several assays for detecting ACPAs were developed in the following years, employing mutated citrullinated Vimentin (MCV-assay), filaggrin-derived peptides (CCP-assay) and viral citrullinated peptides (VCP-assay). A 2006 clinical study showed that anti viral citrullinated peptide (VCP) antibodies of the IgG and IgA isotypes represent a discriminating specific marker of rheumatoid arthritis from other chronic arthritides and disease controls, suggesting an independent production of each isotype. In 2010, ACPA testing has become substantial part of The 2010 ACR-EULAR classification criteria for rheumatoid arthritis.
Proteomics permits the quantitative analysis and detection of changes to proteins or protein biomarkers. Protein biomarkers detect a variety of biological changes, such as protein-protein interactions, post-translational modifications and immunological responses. Protein biomarkers are widely used in diagnostics due to their direct involvement in cellular functions and pathways. Protein biomarkers can provide direct information about the functional state of cells and tissues, offering insights into disease mechanisms. Techniques such as mass spectrometry, immunohistochemistry, ELISA, and flow cytometry are employed to detect protein biomarkers, which can indicate protein presence and quantification. For example, in about 20% of breast cancers, the cancer cells have an overexpression of the HER2 gene, leading to more aggressive tumor growth. HER2 status can be determined using IHC and FISH. HER2-positive breast cancers are treated with targeted therapies that specifically target the HER2 protein, inhibiting the growth of cancer cells.
Sources: en.wikipedia.org
AS9100 Revision C (2009), Quality Management System – Requirements for Aviation, Space and Defense Organizations The update of AS9100 from revision B to C is largely to address the following question: "Our supplier is repeatedly late on delivery and failing to meet our requirements, how is it possible that they still have their AS9100 certificate?" That is, the AS9100C changes are driven by repeated delivery of non-conforming product and repeated late delivery by organizations that held AS9100A/B certifications. Those organizations had documented controls that conformed to the standard, however, there were insufficient processes in place to assure effectiveness of those controls. The response in this AS9100 revision is to elevate the requirements for Risk Management and to make Risk Management an integrated theme throughout the standard. A major challenge to AS9100B-compliant organizations was the new AS9100 auditing standards defined in AS9101 Revision D, which eliminates the clause-based compliance checklist and requires organizations to provide evidence of effectiveness of their systems and processes. Summary of changes between AS9100B and AS9100C:
Central obesity can be a feature of lipodystrophies, a group of diseases that is either inherited, or due to secondary causes (often protease inhibitors, a group of medications against AIDS). Central obesity is a symptom of Cushing's syndrome and is also common in patients with polycystic ovary syndrome (PCOS). Central obesity is associated with glucose intolerance and dyslipidemia. Once dyslipidemia becomes a severe problem, an individual's abdominal cavity would generate elevated free fatty acid flux to the liver. The effect of abdominal adiposity occurs not just in those who are obese, but also affects people who are non-obese and it also contributes to insulin sensitivity. Ghroubi et al. (2007) examined whether abdominal circumference is a more reliable indicator than BMI or the presence of knee osteoarthritis in obese patients. They found that it actually appears to be a factor linked with the presence of knee pain as well as osteoarthritis in obese study subjects. Ghroubi et al. (2007) concluded that a high abdominal circumference is associated with great functional repercussion. Research published in The Lancet (2023) found that high levels of visceral fat were related to poorer cognitive performance. The findings suggest that maintaining a healthy weight and metabolic health may be important for preserving cognitive function.
The histology of ALK-negative ALCL, similar to ALK-positive ALCL, consist of "hallmark" cells that strongly express CD30. Unlike ALK-positive ALCL, however, ALK-negative ALC does not fall into different morphological patterns. The histological of this disease may overlap with and be difficult to distinguish from other CD30-positive T-cell lymphomas or the nodular sclerosis form of Hodgkin lymphoma. Cases in which ALK-negative ALCL is not distinguishable from the latter lymphomas are best diagnosed as peripheral T-cell lymphoma not otherwise specified (PTL, NOS). The histology of ALK-negative ALCL may also overlap with tumors of non–T-cell lineage such as various carcinomas. The differential diagnoses of ambiguous cases may be helped by examining the tumor cells for the expression of certain marker proteins. For example, expression of CD56, MUC1 (also termed EMA for epithelial membrane antigen), and clusterin and strong uniform expression of CD30 support the diagnosis of ALK-negative ALCL over PTL, NOS, while variable CD30 expression and extensive expression of T-cell receptor proteins favor PTCL-NOS over ALK-negative ALCL. Detection of certain gene abnormalities (see next section) may also help distinguishing these diseases.
Sources: en.wikipedia.org
Validation establishes suitability for a new method, while verification confirms that a method works in a specific laboratory. Verification is often used when a validated method is adopted with existing equipment and staff. Both rely on documented acceptance criteria.
Quantification usually compares detector response to a standard curve made from reference standards. The curve may be external, internal, or based on standard addition depending on matrix effects. Results are reported with units and, when required, uncertainty.
Carryover occurs when analyte from a previous injection remains in the system and appears in a later chromatogram. It can come from the injector, column, or tubing. Blank injections and needle washes help detect and reduce it.
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.